GM700SB

GM700SB

Smart and Wireless Companion for Self Diabetes Management

Say goodbye to logbook! With Rightest CARE App, you can now easily manage blood sugar anytime, anywhere.
Bluetooth transmission

Transfers test results to Rightest CARE App wirelessly.

Wide HCT range

Measures glucose value of extreme hematocrit range, like neonate, elder, anemia patient.

Meal markers

Before-and-after meal markers allow you to understand how food affects your blood glucose.

Alternative blood sampling site

Capillary, venous, arterial and neonatal whole blood are applicable.

Auto coding

Eliminates the needs for manual coding and delivers better accuracy than no coding.

Proprietary Rightest™ strip

With this Validus Technology™, Rightest™ strips always deliver high accuracy and precision in readings.

GM700SB meter

Say Goodbye to Logbook

Manage blood glucose and maintain health easily

How it Works

Play Video

1. Insert a GS700 test strip in the socket of the meter. The calibration will be done automatically..

2. Place your blood sample against the edge of sample entry of the strip.

3. After 5 seconds, the test result will appear.

4. Rotate and pull up the test strip from the meter.

Specification

Test stripGS700
CodingAuto coding calibration
Enzyme / Measurement technologyGDH / Electrochemical sensor
Blood sample sourceCapillary, venous, arterial and neonatal whole blood
Minimum sample volume0.75 microliters (0.00075c.c.)
HCT range

Glucose concentrations ≦ 11.1mmol/L(200mg/dL), HCT range 20 – 70%

Glucose concentrations > 11.1mmol/L(200mg/dL), HCT range 20 – 60%

Measuring range0.6 – 33.3 mmol/L (10 – 600mg/dL)
Meter dimensions (L x W x H)82.0 x 45.0 x 15.5 mm (3.22 x 1.77 x 0.61 inch)
Display area (L x W)34.0 x 27.5 mm (1.09 x 1.34 inch)
Weight (with battery)43.0 ± 5 g
Power supply1 CR2032 battery
Memory capacity500 blood glucose test results with date and time
Operating temperature6 – 44℃ (43 – 111°F)
Operating relative humidity10 – 90%
Meter storage conditions-10 – 60°C (14 – 140°F)
Test strip storage conditions4 – 30°C (39 – 86°F), < 90% relative humidity
Bluetooth version4.0
Accuracy

95% of the measured glucose values shall fall within either

Glucose concentrations < 5.5mmol/L (100mg/dL), difference within ± 0.83mmol/L (15mg/dL)

Glucose concentrations ≥ 5.5mmol/L (100mg/dL), bias within ± 15%

Precision

Glucose concentrations < 5.5mmol/L (100mg/dL), SD < 0.28mmol/L (5mg/dL)

Glucose concentrations ≥ 5.5mmol/L (100mg/dL), CV < 5%

Fully comply with ISO 15197:2013 (For other received credentials, please contact us.)